Welcome: HC Electric

Electric Energy Metering Terminal Block and Junction Box

  • Energy Meter Terminal Block FJ6-JTS2C
  • Energy Meter Terminal Block FJ6-JTS2C
  • Energy Meter Terminal Block FJ6-JTS2C
  • Energy Meter Terminal Block FJ6-JTS2C
  • Energy Meter Terminal Block FJ6-JTS2C
Energy Meter Terminal Block FJ6-JTS2CEnergy Meter Terminal Block FJ6-JTS2CEnergy Meter Terminal Block FJ6-JTS2CEnergy Meter Terminal Block FJ6-JTS2CEnergy Meter Terminal Block FJ6-JTS2C

Energy Meter Terminal Block FJ6-JTS2C

  • Model: FJ6/JTS2
  • Structure:One Inlet, one Outlet
  • Section Inlet Wire:16-50mm2 (Panel Connection)
  • Outine Size:78(W)*63(H)*25(T)
  • Product description: Energy Meter Terminal Block
  • INQUIRY
  1. General Introduction

    FJ6/JTS2 series terminal block is designed for wiring in electric control distribution equipment, complete equipment and terminal apparatus, etc. The product is of rated insulation voltage 690V, rated working voltage 380V, max section of inlet terminal conductor 120mm2. According to different circuit number and connection ways, the section of outlet terminal reaches 2.5-120mm2. This product structure has advantages of original structure, firm connection and flexible operation. In addition, it can also serve as electric equipment bus bars, heavy- current terminal block, neutral terminal, grounding terminal, equipotential terminal, etc.

  2. Structural Features

    FJ6/JTS2 series terminal block is composed of conductive part, insulator foot and protective cover, with compact volume and reliable structure. Through its inlet terminal, the conductor can be connected directly (simple connection), or connected with OT lug (panel connection), in addition, this inlet terminal also allows the copper bar not exceeding 30mm to enter, and all connections at the outlet terminal are of the barrel type. The bottom of crimping screw is spherical shape, which takes no damage over the conductor when crimping, and even brings big enough extrusion forve over the conductor and have more reliable contact.

  3. Installation&Use

    There are two ways to install this product: 1. Drill a hole in the bottom plate directly and install (Only for the product whose outline size is 78*63*36, and mounting screw is M5); 2. Install it on TH-35 rail (top-hat rail). It is suggested that multi-cores wire should be used for connecting conductors. And only the conductor is inserted into the bottom of blind hole thoroughly, could the screw be tightened down to prevent wrong connection. When conductor section is small, and conductor insulator can be stuffed into the connection hole, the insulator is allowed to enter into the connection hole on the premise of reliable contact of conductor. If the protective cover is required to open, pinch the lap of protective cover inward slightly, inset a screwdriver into the lap, then rotate it slightly. When to assemble the protective cover, apply the pressure to four laps, and make sure every lap into the hole.

  4. Notification of order

    When ordering, please indicate the model (or order No. and quantity.

    The inlet and outlet wire size of FJ6/JTS2 series terminal block can be customized.